Bacterial Filtration Efficiency (BFE) Tester for Masks

After-sales Service: Support
Warranty: 1 Year
Max Diameter of Workpiece: <500mm
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Bacterial Filtration Efficiency (BFE) Tester for Masks pictures & photos
Bacterial Filtration Efficiency (BFE) Tester for Masks
US $4,000-4,500 / Piece
Min. Order: 1 Piece
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Guangdong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 3 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (31)
  • Overview
  • Product Description
  • Features
  • Product Parameters
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
PW-BFE01
Mass Scope of Workpiece
<900kg
Type
Ventilation Resistance and Pressure Difference Tes
Maxcapacity
<1000KN
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
1000-2000Kg
Power Source
AC220V
Oil Cylinder Position
Under
Power
AC220V 50Hz / 1.2kw
Product Size
L * W * H (860mm * 760mm * 1680mm)
Transport Package
Strong Wooden Case
Trademark
PW
Origin
Dongguan, China
HS Code
8514109000
Production Capacity
1000pieces/Year

Product Description

Product Description

Mask bacterial filtration efficiency (BFE) tester is mainly suitable for measurement and certification departments, scientific research institutes, medical mask production units and their related testing departments for the performance of mask bacterial filtration efficiency test. It mainly conforms to YY0469-2011 Technical Requirements for Medical Surgical Masks, Appendix B, Bacterial Filtration Efficiency (BFE) Test Method, B.1.1.1 Test Instrument Requirements. It also meets the requirements of ASTM F2100, ASTM F2101 and EN 14683 standards.
Bacterial Filtration Efficiency (BFE) Tester for Masks

Features

1. Negative pressure test system, to ensure the safety of the operator

2. Negative pressure cabinet built-in peristaltic pump, A, B two-way six Anderson

3. Peristaltic pump flow size can be set according to the situation

4. Special microbial aerosol generator bacteria liquid fog flow size can be set, atomization effect is good.

5. Industrial microcomputer control

6. high brightness color touch screen.

7. USB interface, support U disk data transfer.

8. Built-in high brightness lighting. Easy to observe.

9. Built-in leakage protection switch to protect the operator's safety.

10. Front glass door, easy for the operator to observe the operation

Product Parameters

Main parameters Parameter range
Model PW-BFE01
Vacuum pump Oil-free rotary vane vacuum pump, the maximum flow rate can reach 57LPM, equipped with silencer, stable airflow.
Aerosol generator flow control Aerosol generator flow control Aerosol generator flow control adopts mass flow control, precise control
I sampling flow rate Anderson sampling flow rate 28.3L/min, resolution: 0.1L/min
II sampling flow rate Anderson sampling flow rate 28.3L/min, resolution: 0.1L/min
I, II sampling with mass flow controller
1 Pneumatic pressure 0-5KPa
II Pneumatic pressure 0-5KPa
Spray flow meter pressure 0-300KPa
Aerosol chamber negative pressure  0-120KPa
Working temperature 0-50 degrees Celsius
Cabinet negative pressure 0-120Pa
Data storage capacity Can download data through U disk
Mass flow controller 0-20L / min, resolution: 0.1 L / min
Peristaltic pump flow rate (0.01~3.0)mL/min
High efficiency air filter characteristics  Filtration efficiency of particles above 0.3um ≥ 99.99%
Aerosol generator mass median diameter Average particle diameter (3.0 ± 0.3) μm, geometric standard deviation ≤ 1.5  
Anderson sampler capture particle size I>7μm, II (4.7 ~ 7) μm, III (3.3 ~ 4.7) μm, IV(2.1 ~ 3.3) μm, V (1.1 ~ 2.1) μm, VI (0.6 ~ 1.1) μm
Aerosol chamber specifications (600×80×5)mm
Positive quality control sampler total number of particles (2200±500)cfu
Negative pressure system ventilation flow 800m3/min
Operation room  dimension (740×940×440)mm
Dimensions 1200×650×2100mm
Instrument noise <65Db(A)
Overall power consumption    <1500W

Company Profile

Bacterial Filtration Efficiency (BFE) Tester for Masks
Bacterial Filtration Efficiency (BFE) Tester for Masks

Company Introduction:

PW (Guangdong) Instruments Co., Ltd. was established in March 2007, a national high-tech enterprise, located in Tongzheng Intelligent Industrial Park, No. 2, North 3rd Road, Tingshan Square, Houjie Town, Dongguan City, Guangdong Province. Through years of operation, the company has gathered a group of talents with considerable qualifications in the industry, and has accumulated a large number of high-quality customers. In order to better serve customers in East China, the company established PW Instruments (Shanghai) Co., Ltd. in Shanghai and set up an instrument exhibition hall and testing center in Suzhou Industrial Park.

Corporate Culture:

Vision: Become a world-renowned instrument manufacturer
Mission: Provide customers with high-quality testing equipment
Values: Customer satisfaction is our aim.



Bacterial Filtration Efficiency (BFE) Tester for Masks
Bacterial Filtration Efficiency (BFE) Tester for Masks


Bacterial Filtration Efficiency (BFE) Tester for Masks
Bacterial Filtration Efficiency (BFE) Tester for Masks


Bacterial Filtration Efficiency (BFE) Tester for Masks
Bacterial Filtration Efficiency (BFE) Tester for Masks


Bacterial Filtration Efficiency (BFE) Tester for Masks
Bacterial Filtration Efficiency (BFE) Tester for Masks
 

Certifications


Bacterial Filtration Efficiency (BFE) Tester for Masks

 

FAQ

Q: Are your company a trading one or a factory?
A: Factory, More than 15 years focusing on test equipment field, 10 years exporting experience.

Q: After an order is placed, when to deliver?
A: Generally about 10-25 days, If we have inventory, we can arrange shipment within 3 days.
Please be aware that our production lead times depend on specific items and item quantities.

Q: What about the warranty with after-sales services?
A: The testing machine is guaranteed for 12 months by PW, we can help you to repair your problem controller freely, even it's not from our factory. After the warranty, the professional after-sale service team will provide perfect technical support and help guests solve problems encountered while using our product, handle guest problems and complaints in a professional and timely.

Q: What about the product's services and quality?
A: Each piece of equipment must be carried out 100% quality examination and test when shipping and delivering goods. Product use training, each of our products provides video training to show you how to install & operate. We can arrange engineer to train the operation of equipment to customer's company when you need. products are widely recognized and trusted by users.
A: Considerate Service Different countries plugs, manually change the voltage from 110V to 220V, insurance indicator.

Q: Can your products be customized?
A: Yes, our product can be customized according to your parameters.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now